REMQ5U7Y1B |
Sound pressure level
|
Cooling
|
Nom.
|
dBA
|
57.0 (5)
|
Standard Accessories
|
Installation and operation manual
|
1
|
|
Connection pipes
|
1
|
Capacity range
|
HP
|
5
|
Operation range
|
Cooling
|
Max.
|
°CDB
|
43.0
|
|
|
Min.
|
°CDB
|
-5.0
|
|
Heating
|
Min.
|
°CWB
|
-20.0
|
|
|
Max.
|
°CWB
|
15.5
|
Maximum number of connectable indoor units
|
64 (3)
|
Compressor
|
Type
|
|
Hermetically sealed scroll compressor
|
Weight
|
Unit
|
kg
|
230
|
Refrigerant
|
Charge
|
TCO2Eq
|
20.2
|
|
GWP
|
|
2,087.5
|
|
Charge
|
kg
|
9.7
|
|
Type
|
|
R-410A
|
Indoor index connection
|
Min.
|
|
62.5
|
|
Max.
|
|
162.5
|
Cooling capacity
|
Prated,c
|
kW
|
14.0 (1)
|
Piping connections
|
HP/LP gas
|
OD
|
mm
|
15.9
|
|
Liquid
|
OD
|
mm
|
9.5
|
|
|
Type
|
|
Braze connection
|
|
Gas
|
OD
|
mm
|
19.1
|
|
|
Type
|
|
Braze connection
|
Sound power level
|
Cooling
|
Nom.
|
dBA
|
78.0 (4)
|
Dimensions
|
Unit
|
Width
|
mm
|
930
|
|
|
Depth
|
mm
|
765
|
|
|
Height
|
mm
|
1,685
|
Fan
|
External static pressure
|
Max.
|
Pa
|
78
|
Power supply
|
Phase
|
|
3N~
|
|
Name
|
|
Y1
|
|
Frequency
|
Hz
|
50
|
|
Voltage
|
V
|
380-415
|
Notes
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m
|
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m
|
|
(3) - Actual number of connectable indoor units depends on the indoor unit type and the connection ratio restriction for the system (50% ≤ CR ≤ 120%)
|
|
(4) - Sound power level is an absolute value that a sound source generates.
|
|
(5) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings.
|
|
(6) - Refer to refrigerant pipe selection or installation manual
|
|
(7) - RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB
|
|
(8) - MSC means the maximum current during start up of the compressor. This unit uses only inverter compressors. Starting current is always ≤ max. running current.
|
|
(9) - In accordance with EN/IEC 61000-3-12, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply wih Ssc ≥ minimum Ssc value
|
|
(10) - MCA must be used to select the correct field wiring size. The MCA can be regarded as the maximum running current.
|
|
(11) - MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker).
|
|
(12) - FLA means the nominal running current of the fan
|
|
(13) - Maximum allowable voltage range variation between phases is 2%.
|
|
(14) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
|
(15) - The AUTOMATIC ESEER value corresponds with normal VRV4 Heat Recovery operation, taking into account advanced energy saving operation functionality (variable refrigerant temperature control operation )
|
|
(16) - The STANDARD ESEER value corresponds with normal VRV4 Heat Recovery operation, not taking into account advanced energy saving operation functionality
|
|
(17) - Sound values are measured in a semi-anechoic room.
|
|
(18) - Soundpressure system [dBA] = 10*log[10^(A/10)+10^(B/10)+10^(C/10)] , with Unit A = A dBA, Unit B = B dBA, Unit C = C dBA
|
|
(19) - EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase
|
|
(20) - Ssc: Short-circuit power
|
|
(21) - For detailed contents of standard accessories, see installation/operation manual
|
|
(22) - Multi combination (10~54HP) data is corresponding with the standard multi combination
|