Specifications Table for FXFA-A

FXFA100AVEB (Preliminary) FXFA20A2VEB (Archived) FXFA25A2VEB (Archived) FXFA32A2VEB (Archived) FXFA40A2VEB (Archived) FXFA50A2VEB (Archived) FXFA63A2VEB (Archived) FXFA80A2VEB (Archived) FXFA100A2VEB (Archived) FXFA125A2VEB (Archived)
Refrigerant Type   R-32
  GWP   675
Piping connections Liquid OD mm 9.52
  Gas OD mm 15.9
  Drain   VP25 (O.D. 32 / I.D. 25)
Dimensions Unit Width mm 840
    Depth mm 840
    Height mm 246
Casing Material   Galvanised steel plate
Weight Unit kg 24.0
Decoration panel 2 Model   BYCQ140E2GFW1, BYCQ140E2GFW1B
  Dimensions Width mm 950
    Height mm 148
  Weight kg 10.3
  Dimensions Depth mm 950
Decoration panel 3 Model   BYCQ140E2P, BYCQ140E2PB
  Dimensions Height mm 106
    Width mm 950
    Depth mm 950
  Weight kg 6.5
Decoration panel Weight kg 5.5
  Model   BYCQ140E2W1, BYCQ140E2W1W, BYCQ140E2W1B
  Dimensions Height mm 65
    Depth mm 950
    Width mm 950
Current - 50Hz Maximum fuse amps (MFA) A 16
Power supply Phase   1~
  Frequency Hz 50/60
  Voltage V 220-240/220
Cooling capacity Total capacity At high fan speed kW   2.20 2.80 3.60 4.50 5.60 7.10 9.00 11.20 14.00
Heating capacity Total capacity At high fan speed kW   2.50 3.20 4.00 5.00 6.30 8.00 10.00 12.50 16.00
Power input - 50Hz Cooling At high fan speed kW   0.017 (1) 0.017 (1) 0.017 (1) 0.018 (1) 0.023 (1) 0.028 (1) 0.045 (1) 0.078 (1) 0.103 (1)
  Heating At high fan speed kW   0.017 (1) 0.017 (1) 0.017 (1) 0.018 (1) 0.023 (1) 0.028 (1) 0.045 (1) 0.078 (1) 0.103 (1)
Dimensions Unit Height mm   204 204 204 204 204 204 246 246 288
    Width mm   840 840 840 840 840 840 840 840 840
    Depth mm   840 840 840 840 840 840 840 840 840
Weight Unit kg   18 18 18 19 21 21 24 24 26
Casing Material     Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate
Fan Air flow rate - 50Hz Cooling At high fan speed m³/min   12.8 12.8 12.8 14.8 15.1 16.6 23.3 28.8 33.0
      At low fan speed m³/min   8.9 8.9 8.9 10.4 10.7 10.7 13.8 13.8 20.6
Refrigerant Type     R-32 R-32 R-32 R-32 R-32 R-32 R-32 R-32 R-32
  GWP     675 675 675 675 675 675 675 675 675
Sound power level Cooling At high fan speed dBA   49.0 49.0 49.0 51.0 51.0 53.0 55.0 60.0 61.0
Sound pressure level Cooling At high fan speed dBA   31.0 31.0 31.0 33.0 33.0 35.0 38.0 43.0 45.0
    At medium fan speed dBA   29.0 29.0 29.0 31.0 31.0 33.0 34.0 37.0 41.0
    At low fan speed dBA   28.0 28.0 28.0 29.0 29.0 30.0 30.0 30.0 36.0
  Heating At high fan speed dBA   31.0 31.0 31.0 33.0 33.0 35.0 38.0 43.0 45.0
    At medium fan speed dBA   29.0 29.0 29.0 31.0 31.0 33.0 34.0 37.0 41.0
    At low fan speed dBA   28.0 28.0 28.0 29.0 29.0 30.0 30.0 30.0 36.0
Piping connections Liquid Type     Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection
    OD mm   6 6 6 6 6 6 6 10 10
  Gas Type     Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection
    OD mm   9.52 9.52 9.52 12.7 12.7 12.7 12.7 15.9 15.9
  Drain     VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25) VP25 (O.D. 32 / I.D. 25)
Decoration panel Model     BYCQ140E2W1, BYCQ140E2W1W, BYCQ140E2W1B BYCQ140E2W1, BYCQ140E2W1W, BYCQ140E2W1B BYCQ140E2W1, BYCQ140E2W1W, BYCQ140E2W1B BYCQ140E2W1, BYCQ140E2W1W, BYCQ140E2W1B BYCQ140E2W1, BYCQ140E2W1W, BYCQ140E2W1B BYCQ140E2W1, BYCQ140E2W1W, BYCQ140E2W1B BYCQ140E2W1, BYCQ140E2W1W, BYCQ140E2W1B BYCQ140E2W1, BYCQ140E2W1W, BYCQ140E2W1B BYCQ140E2W1, BYCQ140E2W1W, BYCQ140E2W1B
  Dimensions Height mm   65 65 65 65 65 65 65 65 65
    Width mm   950 950 950 950 950 950 950 950 950
    Depth mm   950 950 950 950 950 950 950 950 950
  Weight kg   5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5
Decoration panel 2 Model     BYCQ140E2GFW1, BYCQ140E2GFW1B BYCQ140E2GFW1, BYCQ140E2GFW1B BYCQ140E2GFW1, BYCQ140E2GFW1B BYCQ140E2GFW1, BYCQ140E2GFW1B BYCQ140E2GFW1, BYCQ140E2GFW1B BYCQ140E2GFW1, BYCQ140E2GFW1B BYCQ140E2GFW1, BYCQ140E2GFW1B BYCQ140E2GFW1, BYCQ140E2GFW1B BYCQ140E2GFW1, BYCQ140E2GFW1B
  Dimensions Height mm   148 148 148 148 148 148 148 148 148
    Width mm   950 950 950 950 950 950 950 950 950
    Depth mm   950 950 950 950 950 950 950 950 950
  Weight kg   10.3 10.3 10.3 10.3 10.3 10.3 10.3 10.3 10.3
Decoration panel 3 Model     BYCQ140E2P, BYCQ140E2PB BYCQ140E2P, BYCQ140E2PB BYCQ140E2P, BYCQ140E2PB BYCQ140E2P, BYCQ140E2PB BYCQ140E2P, BYCQ140E2PB BYCQ140E2P, BYCQ140E2PB BYCQ140E2P, BYCQ140E2PB BYCQ140E2P, BYCQ140E2PB BYCQ140E2P, BYCQ140E2PB
  Dimensions Height mm   106 106 106 106 106 106 106 106 106
    Width mm   950 950 950 950 950 950 950 950 950
    Depth mm   950 950 950 950 950 950 950 950 950
  Weight kg   6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5
Air filter Type     Resin net Resin net Resin net Resin net Resin net Resin net Resin net Resin net Resin net
Standard Accessories Washer for hanger bracket   8 8 8 8 8 8 8 8 8
  Wire clamp material   7 7 7 7 7 7 7 7 7
  Clamp for drain hose   1 1 1 1 1 1 1 1 1
  Clamps   1 1 1 1 1 1 1 1 1
  Drain hose   1 1 1 1 1 1 1 1 1
  Installation and operation manual   1 1 1 1 1 1 1 1 1
  Installation guide   1 1 1 1 1 1 1 1 1
  Insulation for fitting   2 2 2 2 2 2 2 2 2
  Screws   4 4 4 4 4 4 4 4 4
  Sealing pads   1 1 1 1 1 1 1 1 1
Power supply Phase     1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~
  Frequency Hz   50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60
  Voltage V   220-240/220 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220
Current - 50Hz Maximum fuse amps (MFA) A   6 6 6 6 6 6 6 6 6
Notes   (1) - Values are valid for the factory setting. (1) - Values are valid for the factory setting. (1) - Values are valid for the factory setting. (1) - Values are valid for the factory setting. (1) - Values are valid for the factory setting. (1) - Values are valid for the factory setting. (1) - Values are valid for the factory setting. (1) - Values are valid for the factory setting. (1) - Values are valid for the factory setting.
    (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB
    (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB
    (4) - The sound power level is an absolute value indicating the power which a sound source generates. (4) - The sound power level is an absolute value indicating the power which a sound source generates. (4) - The sound power level is an absolute value indicating the power which a sound source generates. (4) - The sound power level is an absolute value indicating the power which a sound source generates. (4) - The sound power level is an absolute value indicating the power which a sound source generates. (4) - The sound power level is an absolute value indicating the power which a sound source generates. (4) - The sound power level is an absolute value indicating the power which a sound source generates. (4) - The sound power level is an absolute value indicating the power which a sound source generates. (4) - The sound power level is an absolute value indicating the power which a sound source generates.
    (5) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (5) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (5) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (5) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (5) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (5) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (5) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (5) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (5) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
    (6) - Maximum allowable voltage range variation between phases is 2%. (6) - Maximum allowable voltage range variation between phases is 2%. (6) - Maximum allowable voltage range variation between phases is 2%. (6) - Maximum allowable voltage range variation between phases is 2%. (6) - Maximum allowable voltage range variation between phases is 2%. (6) - Maximum allowable voltage range variation between phases is 2%. (6) - Maximum allowable voltage range variation between phases is 2%. (6) - Maximum allowable voltage range variation between phases is 2%. (6) - Maximum allowable voltage range variation between phases is 2%.
    (7) - MCA/MFA: MCA = 1.1 x FLA (7) - MCA/MFA: MCA = 1.1 x FLA (7) - MCA/MFA: MCA = 1.1 x FLA (7) - MCA/MFA: MCA = 1.1 x FLA (7) - MCA/MFA: MCA = 1.1 x FLA (7) - MCA/MFA: MCA = 1.1 x FLA (7) - MCA/MFA: MCA = 1.1 x FLA (7) - MCA/MFA: MCA = 1.1 x FLA (7) - MCA/MFA: MCA = 1.1 x FLA
    (8) - Instead of a fuse, use a circuit breaker (8) - Instead of a fuse, use a circuit breaker (8) - Instead of a fuse, use a circuit breaker (8) - Instead of a fuse, use a circuit breaker (8) - Instead of a fuse, use a circuit breaker (8) - Instead of a fuse, use a circuit breaker (8) - Instead of a fuse, use a circuit breaker (8) - Instead of a fuse, use a circuit breaker (8) - Instead of a fuse, use a circuit breaker
    (9) - Select wire size based on the value of MCA (9) - Select wire size based on the value of MCA (9) - Select wire size based on the value of MCA (9) - Select wire size based on the value of MCA (9) - Select wire size based on the value of MCA (9) - Select wire size based on the value of MCA (9) - Select wire size based on the value of MCA (9) - Select wire size based on the value of MCA (9) - Select wire size based on the value of MCA
    (10) - BYCQ140E2W1: pure white standard panel with grey louvers; BYCQ140E2W1W: pure white standard panel with white louvers; BYCQ140E2W1B: black standard panel with black louvers. (10) - BYCQ140E2W1: pure white standard panel with grey louvers; BYCQ140E2W1W: pure white standard panel with white louvers; BYCQ140E2W1B: black standard panel with black louvers. (10) - BYCQ140E2W1: pure white standard panel with grey louvers; BYCQ140E2W1W: pure white standard panel with white louvers; BYCQ140E2W1B: black standard panel with black louvers. (10) - BYCQ140E2W1: pure white standard panel with grey louvers; BYCQ140E2W1W: pure white standard panel with white louvers; BYCQ140E2W1B: black standard panel with black louvers. (10) - BYCQ140E2W1: pure white standard panel with grey louvers; BYCQ140E2W1W: pure white standard panel with white louvers; BYCQ140E2W1B: black standard panel with black louvers. (10) - BYCQ140E2W1: pure white standard panel with grey louvers; BYCQ140E2W1W: pure white standard panel with white louvers; BYCQ140E2W1B: black standard panel with black louvers. (10) - BYCQ140E2W1: pure white standard panel with grey louvers; BYCQ140E2W1W: pure white standard panel with white louvers; BYCQ140E2W1B: black standard panel with black louvers. (10) - BYCQ140E2W1: pure white standard panel with grey louvers; BYCQ140E2W1W: pure white standard panel with white louvers; BYCQ140E2W1B: black standard panel with black louvers. (10) - BYCQ140E2W1: pure white standard panel with grey louvers; BYCQ140E2W1W: pure white standard panel with white louvers; BYCQ140E2W1B: black standard panel with black louvers.
    (11) - The BYCQ140E2W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140E2W1W decoration panel in enviroments exposed to concentrations of dirt. (11) - The BYCQ140E2W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140E2W1W decoration panel in enviroments exposed to concentrations of dirt. (11) - The BYCQ140E2W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140E2W1W decoration panel in enviroments exposed to concentrations of dirt. (11) - The BYCQ140E2W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140E2W1W decoration panel in enviroments exposed to concentrations of dirt. (11) - The BYCQ140E2W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140E2W1W decoration panel in enviroments exposed to concentrations of dirt. (11) - The BYCQ140E2W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140E2W1W decoration panel in enviroments exposed to concentrations of dirt. (11) - The BYCQ140E2W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140E2W1W decoration panel in enviroments exposed to concentrations of dirt. (11) - The BYCQ140E2W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140E2W1W decoration panel in enviroments exposed to concentrations of dirt. (11) - The BYCQ140E2W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140E2W1W decoration panel in enviroments exposed to concentrations of dirt.
    (12) - Contains fluorinated greenhouse gases (12) - Contains fluorinated greenhouse gases (12) - Contains fluorinated greenhouse gases (12) - Contains fluorinated greenhouse gases (12) - Contains fluorinated greenhouse gases (12) - Contains fluorinated greenhouse gases (12) - Contains fluorinated greenhouse gases (12) - Contains fluorinated greenhouse gases (12) - Contains fluorinated greenhouse gases