Specifications Table for FWS-AT

FWS02AATV3 FWS03AATV3 FWS06AATV3 FWS08AATV3
Cooling capacity (standard conditions) Sensible capacity 2-pipe Low kW 1.04 (1) 1.25 (1) 2.31 (1) 3.04 (1)
    High kW 1.49 (1) 2.09 (1) 3.62 (1) 5.87 (1)
  Total capacity 2-pipe Low kW 1.35 (1) 1.75 (1) 2.99 (1) 4.10 (1)
    High kW 1.94 (1) 2.91 (1) 4.48 (1) 7.93 (1)
Heating capacity (standard conditions) Capacity 2-pipe Low kW 1.50 (2) 1.76 (2) 3.36 (2) 4.39 (2)
    High kW 2.15 (2) 2.94 (2) 4.88 (2) 8.37 (2)
Power input Low kW 0.01 0.01 0.01 0.013
  High kW 0.019 0.016 0.033 0.087
Dimensions Unit Height mm 535 535 535 535
    Width mm 584 794 1,000 1,214
    Depth mm 224 224 224 249
Weight Unit kg 16.9 22.1 26.6 35.4
Fan Air flow rate Low m³/h 211 241 470 642
    High m³/h 344 442 785 1,393
Total sound power level Low dBA 40 (4) 36 (4) 43 (4) 49 (4)
  High dBA 50 (4) 48 (4) 56 (4) 67 (4)
Sound pressure level Low dBA 35 (6) 31 (6) 38 (6) 44 (5)
  High dBA 45 (6) 43 (6) 51 (6) 62 (5)
Water flow Cooling Low l/h 234 (1) 302 (1) 515 (1) 706 (1)
    High l/h 337 (1) 503 (1) 774 (1) 1,376 (1)
  Heating High l/h 373 (2) 506 (2) 866 (2) 1,455 (2)
    Low l/h 260 (2) 301 (2) 575 (2) 764 (2)
  Water pressure drop Cooling Low kPa 6 (1) 5 (1) 7 (1) 6 (1)
      High kPa 12 (1) 11 (1) 14 (1) 20 (1)
    Heating Low kPa 6 (2) 5 (2) 7 (2) 6 (2)
      High kPa 12 (2) 11 (2) 14 (2) 18 (2)
Allowed water temperature Cooling Min. °C 5 5 5 5
    Max. °C 95.0 95.0 95.0 95.0
  Heating Min. °C 5.00 5.00 5.00 5.00
    Max. °C 95.000 95.000 95.000 95.000
Piping connections Drain OD mm 16 16 16 16
Water connections Primary coil inch 1/2" 1/2" 1/2" 3/4 "
  Additional coil inch   1/2"
Power supply Type   230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50
  Phase   1~ 1~ 1~ 1~
  Frequency Hz 50 50 50 50
  Voltage V 230 230 230 230
Notes (1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. (1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. (1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K. (1) - Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K.
  (2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K. (2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K. (2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K. (2) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 45°C, water temperature drop 5K.
  (3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K. (3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K. (3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K. (3) - Heating: indoor temp. 20°CDB, 15°CWB; entering water temp. 65°C, water temperature drop 10K.
  (4) - Sound power level according to ISO3741 (4) - Sound power level according to ISO3741 (4) - Sound power level according to ISO3741 (4) - Sound power level according to ISO3741
  (5) - SL: The silent fan level of the air flow rate setting (5) - SL: The silent fan level of the air flow rate setting (5) - SL: The silent fan level of the air flow rate setting (5) - The sound pressure level is measured via a microphone at 1m distance of the unit.
  (6) - The sound pressure level is measured via a microphone at 1m distance of the unit. (6) - The sound pressure level is measured via a microphone at 1m distance of the unit. (6) - The sound pressure level is measured via a microphone at 1m distance of the unit.