Specifications Table for FTXM-R / RXM-A9

FTXM25R2V1B / RXM25A5V1B9 FTXM25R5V1B / RXM25A5V1B9 FTXM35R2V1B / RXM35A5V1B9 FTXM35R5V1B / RXM35A5V1B9 FTXM50R2V1B / RXM50A5V1B9
Cooling capacity Min. kW 1.30 1.30 1.40 1.40 1.70
  Nom. kW 2.50 2.50 3.40 3.40 5.00
  Max. kW 3.20 3.20 4.00 4.00 6.00
Heating capacity Min. kW 1.30 1.30 1.40 1.40 1.70
  Nom. kW 2.80 2.80 4.00 4.00 5.80
  Max. kW 4.70 4.70 5.20 5.20 7.70
Nominal efficiency EER   4.50 4.50 4.23 4.23 3.68
  COP   5.00 5.00 4.04 4.04 4.00
  Annual energy consumption kWh 278 278 402 402 679
  Energy labeling Directive Cooling   A A A A A
    Heating   A A A A A
Space cooling Energy efficiency class   A+++ A+++ A+++ A+++ A++
  Capacity Pdesign kW 2.50 2.50 3.40 3.40 5.00
  SEER   8.65 8.65 8.65 8.65 7.41
  Annual energy consumption kWh/a 101 101 137 137 236
Space heating (Average climate) Energy efficiency class   A+++ A+++ A+++ A+++ A++
  Capacity Pdesign kW 2.40 2.40 2.50 2.50 4.60
  SCOP/A   5.10 5.10 5.10 5.10 4.71
  Pdh Heating capacity at -10° kW 2.30 2.30 2.35 2.35 3.85
  Annual energy consumption kWh/a 659 659 686 686 1368
Energy Efficiency Range A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D
Notes (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range
  (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data
  (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.