Specifications Table for FHA-A / RZAG-MY1

FHA35AVEB / FHA35AVEB / RZAG71M7Y1B FHA35AVEB / FHA35AVEB / FHA35AVEB / RZAG71M7Y1B FHA50AVEB / FHA50AVEB / RZAG71M7Y1B FHA71AVEB / RZAG71M7Y1B FHA50AVEB / FHA50AVEB / FHA50AVEB / RZAG100M7Y1B FHA50AVEB / FHA50AVEB / RZAG100M7Y1B FHA71AVEB / FHA71AVEB / RZAG100M7Y1B
Outdoor unit RZAG71M7Y1B RZAG71M7Y1B RZAG71M7Y1B RZAG71M7Y1B
Cooling capacity Nom. kW 6.80 (1) 6.80 (1) 6.80 (1) 6.80 (1)
Heating capacity Nom. kW 7.50 (2) 7.50 (2) 7.50 (2) 7.50 (2)
Space cooling Energy efficiency class   A++ A++ A++ A++
  Capacity Pdesign kW 6.80 6.80 6.80 6.80
  SEER   7.80 7.58 6.55 7.11
  Annual energy consumption kWh/a 305 314 363 335
Space heating (Average climate) Energy efficiency class   A+ A+ A+ A+
  Capacity Pdesign kW 4.70 4.70 4.70 4.70
  SCOP/A   4.43 4.33 4.32 4.32
  Annual energy consumption kWh/a 1485 1520 1523 1523
Energy Efficiency Range A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D
Notes (1) - Cooling: T2: indoor temp. 26,6°CDB, 19,4°CWB, outdoor temp. 48°CDB [Btu/hr/W] (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Cooling: T2: indoor temp. 26,6°CDB, 19,4°CWB, outdoor temp. 48°CDB [Btu/hr/W] (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Cooling: T2: indoor temp. 26,6°CDB, 19,4°CWB, outdoor temp. 48°CDB [Btu/hr/W] (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
Cooling capacity Nom. kW         9.50 (1) 9.50 (1) 9.50 (1)
Space cooling SEER           9.04 8.62 9.44
  Annual energy consumption kWh/a         368 386 352
  Capacity Pdesign kW         9.50 9.50 9.50
  Energy efficiency class           A+++ A+++ A+++
Space heating (Average climate) Capacity Pdesign kW         7.80 7.80 7.80
  SCOP/A           4.73 4.54 4.63
  Energy efficiency class           A++ A+ A++
  Annual energy consumption kWh/a         2,309 2,405 2,359
Heating capacity Nom. kW         10.8 (2) 10.8 (2) 10.8 (2)