| FBA50A2VEB9 / RXS50L2V1B | FBA60A2VEB9 / RXS60L2V1B | ||||
|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 5.70 | ||
| Space cooling | SEER | 5.86 | |||
| Annual energy consumption | kWh/a | 340 | |||
| Capacity | Pdesign | kW | 5.70 | ||
| Energy efficiency class | A+ | ||||
| Space heating (Average climate) | Capacity | Pdesign | kW | 4.60 | |
| SCOP/A | 4.01 | ||||
| Energy efficiency class | A+ | ||||
| Pdh Heating capacity at -10° | kW | 3.91 | |||
| Annual energy consumption | kWh/a | 1,606 | |||
| Nominal efficiency | Annual energy consumption | kWh | 826 | ||
| EER | 3.45 | ||||
| COP | 37.10 | ||||
| Energy labeling Directive | Cooling | A | |||
| Heating | A | ||||
| Heating capacity | Nom. | kW | 7.00 | ||
| Notes | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | |||||
| (3) - See separate drawing for operation range | |||||
| (4) - See separate drawing for electrical data | |||||
| Outdoor unit | RXS50L2V1B | ||||
| Cooling capacity | Nom. | kW | 5.00 | ||
| Heating capacity | Nom. | kW | 5.50 | ||
| Nominal efficiency | EER | 3.52 | |||
| COP | 38.30 | ||||
| Annual energy consumption | kWh | 710 | |||
| Energy labeling Directive | Cooling | A | |||
| Heating | A | ||||
| Space cooling | Energy efficiency class | A++ | |||
| Capacity | Pdesign | kW | 5.00 | ||
| SEER | 6.21 | ||||
| Annual energy consumption | kWh/a | 282 | |||
| Space heating (Average climate) | Energy efficiency class | A+ | |||
| Capacity | Pdesign | kW | 4.40 | ||
| SCOP/A | 4.06 | ||||
| Pdh Heating capacity at -10° | kW | 3.73 | |||
| Annual energy consumption | kWh/a | 1517 | |||
| Energy Efficiency Range | A+++ ~ D | ||||