Specifications Table for ARXM-R

ARXM25R5V1B ARXM35R5V1B ARXM50R2V1B ARXM50R5V1B ARXM60R5V1B ARXM60R2V1B ARXM71R5V1B ARXM71R2V1B
Dimensions Unit Height mm 550 550 734 734 734 734 734 734
    Width mm 765 765 954 954 954 954 954 954
    Depth mm 285 285 401 401 401 401 401 401
Weight Unit kg 32 32 49.0 49.0 49.0 49.0 49.0 49.0
Compressor Type   Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor
Operation range Cooling Ambient Min. °CDB -10 -10 -10 -10 (4) (5), -10 (4) (5) -10 -10 -10 -10
      Max. °CDB 50, 46 50, 46 50, 46 50 (4), 46 (5) 46 46 46 46
  Heating Ambient Min. °CWB -15 -15 -15
      Max. °CWB 18 18 18
Sound pressure level Cooling Nom. dBA 46 49 48.0 48.0 48.0 48.0 52.0 52.0
  Heating Nom. dBA 47 49 49.0 49.0 49.0 49.0 52.0 52.0
Refrigerant Charge kg 0.76 0.76 1.15 1.15 1.15 1.15 1.15 1.15
  Charge tCO2Eq 0.52 0.52 0.780 0.780 0.780 0.780 0.780 0.780
  GWP   675 675 675.0 675.0 675.0 675.0 675.0 675.0
Piping connections Piping length OU - IU Max. m 20 20 30 30 30 30 30 30
  Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.035 (for piping length exceeding 10m) 0.035 (for piping length exceeding 10m)
  Level difference IU - OU Max. m 15 15 20.0 20.0 20.0 20.0 20.0 20.0
Standard Accessories Installation manual 1 1 1 1 1 1 1 1
  Refrigerant charge label 1 1 1 1 1 1 1 1
  Multilingual fluorinated greenhouse gases labels 1 1 1 1 1 1 1 1
  Drain plug 1 1 1 1 1 1 1 1
Power supply Frequency Hz 50 50 50 50 50 50 50 50
Standard Accessories Drain cap     3 3 3 3 3 3
Notes       (1) - Only possible in combination with CTXM*N2V1B, ATXM*N2V1B, FTXM*N2V1B
        (2) - Only possible in combination with CTXM*M2V1B, ATXM*M2V1B, FTXM*M2V1B, FVXM*FV1B, FCAG*AVEB, FFA*A2VEB9,FBA*A2VEB9, FHA*AVEB9, FDXM*F3V1B9, FNA*A2VEB9, ADEA*A2VEB·