FTXF20C5V1B / RXF20C5V1B |
FTXF25C5V1B / RXF25C5V1B |
FTXF35C5V1B / RXF35C5V1B |
FTXF42C5V1B / RXF42C5V1B |
Cooling capacity |
Min. |
kW |
1.3 |
1.3 |
1.3 |
1.4 |
|
Nom. |
kW |
2.00 |
2.50 |
3.30 |
4.20 |
|
Max. |
kW |
2.4 |
2.8 |
3.8 |
4.3 |
Heating capacity |
Min. |
kW |
1.30 |
1.30 |
1.30 |
1.40 |
|
Nom. |
kW |
2.40 |
2.80 |
3.50 |
4.60 |
|
Max. |
kW |
3.30 |
3.70 |
4.40 |
5.00 |
Nominal efficiency |
EER |
|
3.38 |
3.21 |
3.30 |
3.30 |
|
COP |
|
3.69 |
3.64 |
3.72 |
3.70 |
|
Energy labeling Directive |
Cooling |
|
A |
A |
A |
A |
|
|
Heating |
|
A |
A |
A |
A |
Space cooling |
Capacity |
Pdesign |
kW |
2.00 |
2.50 |
3.50 |
4.20 |
|
Energy efficiency class |
|
A++ |
A++ |
A++ |
A++ |
|
SEER |
|
6.22 |
6.22 |
6.22 |
6.50 |
|
Annual energy consumption |
kWh/a |
113 |
141 |
197 |
226 |
Space heating (Average climate) |
Capacity |
Pdesign |
kW |
2.20 |
2.40 |
2.60 |
3.30 |
|
Energy efficiency class |
|
A+ |
A+ |
A+ |
A+ |
|
SCOP/A |
|
4.11 |
4.11 |
4.11 |
4.30 |
|
Annual energy consumption |
kWh/a |
749 |
817 |
885 |
1,075 |
Notes |
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified |
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified |
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified |
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified |
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series |
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series |
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series |
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series |
|
(3) - See separate drawing for electrical data |
(3) - See separate drawing for electrical data |
(3) - See separate drawing for electrical data |
(3) - See separate drawing for electrical data |