Specifications Table for ATXF-C / ARXF-C

ATXF20C5V1B / ARXF20C5V1B ATXF25C5V1B / ARXF25C5V1B ATXF35C5V1B / ARXF35C5V1B ATXF42C5V1B / ARXF42C5V1B
Cooling capacity Min. kW 1.3 1.3 1.3 1.4
  Nom. kW 2.00 2.50 3.30 4.20
  Max. kW 2.4 2.8 3.8 4.3
Heating capacity Min. kW 1.30 1.30 1.30 1.40
  Nom. kW 2.40 2.80 3.50 4.60
  Max. kW 3.30 3.70 4.40 5.00
Nominal efficiency EER   3.33 3.19 3.23 3.27
  COP   3.74 3.55 4.16 3.70
  Energy labeling Directive Cooling   A A A A
    Heating   A A A A
Space cooling Capacity Pdesign kW 2.00 2.50 3.50 4.20
  Energy efficiency class   A++ A++ A++ A++
  SEER   6.12 6.19 6.18 6.45
  Annual energy consumption kWh/a 114 141 198 228
Space heating (Average climate) Capacity Pdesign kW 2.20 2.40 2.60 3.30
  Energy efficiency class   A+ A+ A+ A+
  SCOP/A   4.07 4.03 4.03 4.25
  Annual energy consumption kWh/a 757 835 902 1,086
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series
  (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data